Resources

Transformer Knowledge Base & Buying Guides

Unbalanced Line-to-Neutral Voltages

Unbalanced Line-to-Neutral Voltages? Check the X0 Connection First — and Know When Not To

If your meter shows 135 V on one phase-to-neutral leg and 330 V on another while line-to-line reads…

Read more →
How to Tell If Your Transformer Is Delta or Wye from the Nameplate

How to Tell If Your Transformer Is Delta or Wye from the Nameplate

Most of the time, the nameplate already tells you the answer. You just have to know where to…

Read more →
Bonding the Main Bonding Jumper

Bonding the Main Bonding Jumper: Mistakes That Cause Circulating Currents

A second bond does not put 30 to 50 percent of neutral current on the conduit. A 3…

Read more →
Autotransformers vs Isolation Transformers

Autotransformers vs Isolation Transformers: Cost vs Safety — Which Should You Buy?

If you’re staring at two quotes for the same kVA and one is half the price, you’re not…

Read more →
Resistance Grounding vs Solidly Grounded Wye

Resistance Grounding vs Solidly Grounded Wye: Pros and Cons

Choosing between resistance grounding and a solidly grounded wye is not a pros and cons exercise. Three gates…

Read more →
Grounding the X0 Neutral Correctly

Grounding the X0 Neutral Correctly: A Step-by-Step Field Guide

Grounding X0 is not one bolt. It is four decisions: is this a separately derived system, where is…

Read more →
NEC Article 450

NEC Article 450: What the Code Requires for Transformer Installations

Ask ten electricians what Article 450 requires and nine will quote the 125 percent rule. That rule is…

Read more →
How to Parallel Different Vector Groups Without Damaging Your Bank

How to Parallel Different Vector Groups Without Damaging Your Bank

You can parallel transformers with different vector groups only when the clock numbers differ by four or eight.…

Read more →
Harmonic-Rich Loads

Harmonic-Rich Loads? Why Your Data Center Needs a Delta-Wye Transformer

A delta-wye transformer does not clean up a data center’s harmonics. Its delta winding absorbs the third, ninth…

Read more →
Generator Step-Up and Utility Interface

Generator Step-Up and Utility Interface: Wye-Delta in Generation

A generator step-up transformer is named from the grid end. The high side is wye, solidly grounded. The…

Read more →
25kV Delta to 600Y/347V

25kV Delta to 600Y/347V: Why Canadian Facilities Use This Configuration

A Canadian building runs on 600Y/347 V because 600 V is the highest voltage that still counts as…

Read more →
Delta-Wye Transformers for 480V to 208Y

Delta-Wye Transformers for 480V to 208Y/120V Commercial Service

A 480 V to 208Y/120 V commercial transformer is sized by three numbers, and only one of them…

Read more →